Top core slitting machine producing company: Adjustment under heavy load or short circuit conditions is not allowed: Under heavy load or short circuit conditions on the transformer, tap changer adjustment may cause arcing or excessive current, resulting in damage to the tap changer or transformer. Obey the operating procedures and safety measures: When operating the on-load pressure regulating device, you need to abide by the operating procedures and safety measures, such as wearing protective equipment and following the operating procedures to ensure safe operation. In summary, it is not allowed to operate under live conditions, frequent adjustments, heavy loads or adjustments under short-circuit conditions. When operating the on-load pressure regulating device, the operating procedures and safety measures should be followed to ensure safe and stable operation. Read more details on transformer core cutting line.
Why does the current source inverter need a larger transformer capacity? Current source inverter is a common type of inverter. Its control method adopts current loop control, which has the advantages of high precision and strong adaptability, and is widely used in industrial production. Due to the working characteristics of the current source inverter, a large transformer capacity is required for the following reasons: The current source inverter adopts the intermediate inductance: the current source inverter adopts the intermediate inductor, which can realize the phase difference between the output voltage and the current, so as to realize the frequency conversion control. However, since the intermediate inductor needs to withstand large current and voltage, it is necessary to select a transformer with a larger capacity to ensure the normal operation of the inductor.
Power Quality and Distribution Transformers – The efficiency of distribution transformer substations is significantly affected by power quality. These transformers, which are critical components of the electrical distribution system, convert high-voltage electricity into lower voltage levels suitable for end-use applications. The performance and efficiency of these transformers largely depend on the quality of power they receive. Poor power quality, characterized by voltage sags, swells, harmonics, and flicker, can lead to increased losses in power distribution transformers. These losses can be categorized into two types: core losses and copper losses. Core losses occur due to variations in the magnetic field within the transformer’s core, while copper losses occur due to the resistance of the transformer’s windings. Both these losses are exacerbated under conditions of poor power quality, leading to decreased efficiency of the transformer.
The cut to length line is a special equipment for the production of transformer core, is our latest generation of cross shear line. This cut to length production line is used for shearing, O punching and V notch of transformer core sheet. The special point of this ctl line is that two O punch and one V notch can work at the same time to produce transformer core pieces with 3, 5, 7 steps in vertical direction and 3, 5, 7 steps in horizontal direction.
As a professional electrical equipment manufacturer in China, Canwin specialized in dry type transformers, electrical equipment for over 20 years. Canwin electrical products manufacturer adopts large-scale, intelligent electrical machinery equipment manufacturing mode, and strive to achieve high quality, high efficiency, low cost operation.Our electrical machinery products including cut to length lines, china slitting lines and foil winding machines.
Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.
Power distribution cabinet transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It lowers the network voltage of 10(6)kV or 35kV to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60)Hz, three-phase maximum rated capacity 2500kVA(single-phase maximum rated capacity 833kVA, generally not recommended to use single-phase transformer), can be used in the indoor (outdoor), the capacity of 315kVA and below can be installed on the rod, the ambient temperature is not higher than 40℃, not less than -25℃, The maximum daily average temperature is 30℃, the maximum annual average temperature is 20℃, the relative humidity is not more than 90%(the ambient temperature is 25℃), and the altitude is not more than 1000m.
The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. Discover even more information on canwindg.com
The metal laser cutting machine focuses the laser emitted from the laser into a laser beam with high power density through the optical path system. The laser beam irradiates the surface of the workpiece to make the workpiece reach the melting point or boiling point. At the same time, the high-pressure gas coaxial with the beam blows away the molten or gasified metal. With the movement of the relative position between the beam and the workpiece, the material will finally form a slit, so as to achieve the purpose of cutting. Laser cutting process uses invisible light beam to replace the traditional mechanical knife. It has the characteristics of high precision, fast cutting, not limited to the limitation of cutting pattern, automatic typesetting, material saving, smooth incision and low processing cost. It will gradually improve or replace the traditional metal cutting process equipment.Want to konw more about metal cutting machine, contact us, one of the most professional metal laser cutting machine manufacturers & suppliers in China.
As a professional energy storage system manufacturer, Canwin specialized in battery energy storage system and containerized energy storage system manufacturing. An energy storage system, often abbreviated as ESS, is a device or group of devices assembled together, capable of storing energy in order to supply electrical energy at a later time. In the energy storage systems, the lithium energy storage battery only interacts with the energy storage converter at high voltage, and the converter takes power from the AC grid to charge the battery pack. Or the battery pack supplies power to the converter, and the electric energy is converted into AC by the converter and sent to the AC power grid.
Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.