Top cut to length line supplier

High quality dry type power transformer supplier factory: Why do transformers use silicon steel sheets as iron cores? Transformers use silicon steel sheets as iron cores because silicon steel sheets have high magnetic permeability and low resistance. In a transformer, the iron core mainly undertakes the role of conducting magnetic flux. Therefore, the magnetic permeability of the iron core is very critical. Silicon steel sheet is a specially treated steel with very high magnetic permeability, can effectively conduct magnetic flux, and can reduce the loss of magnetic flux and eddy current loss. In addition, the transformer will produce electromagnetic induction phenomenon during the working process, which will generate eddy current in the iron core. These eddy currents cause loss of energy and heating of the core, reducing the efficiency of the transformer. The silicon steel sheet has low resistance characteristics, which can reduce eddy current loss and improve the efficiency of the transformer. Therefore, using silicon steel sheet as the material of the transformer core can improve the efficiency of the transformer, reduce energy loss, and reduce heat generation of the transformer, thereby prolonging the service life of the transformer. Find even more details at cut to length line.

Current source inverter has a higher power factor: The current source inverter has a higher power factor, which can achieve higher power factor correction, thereby reducing grid harmonic pollution. However, since a higher power factor requires larger capacitor support, a transformer with a larger capacity needs to be selected to meet the power supply requirements of the capacitor. Current source inverter needs additional power supply: The circuit of current source inverter needs additional power supply to ensure the normal operation of the current loop control. These additional power sources need sufficient capacity to support, so a transformer with a larger capacity needs to be selected to meet the power supply requirements. Therefore, the current source inverter needs a larger transformer capacity to ensure the normal operation of the intermediate inductor, support the power supply of the capacitor and meet the power supply requirements. When selecting a transformer, it needs to be selected according to the actual electrical parameters and performance requirements to ensure the normal operation and stability of the inverter.

Power quality plays a crucial role in the performance and longevity of distribution transformer substation. Poor power quality can lead to increased losses, reduced efficiency, and shorter equipment lifespan. Therefore, effective strategies for power quality management are indispensable for the optimal operation of distribution transformers. Harmonic currents, particularly those of higher frequencies, can significantly affect the performance of transformers. These currents are produced by non-linear loads such as computers, variable speed drives, and certain types of lighting systems, causing distortions in the sinusoidal waveform of the electrical supply.

The cut to length line is a special equipment for the production of transformer core, is our latest generation of cross shear line. This cut to length production line is used for shearing, O punching and V notch of transformer core sheet. The special point of this ctl line is that two O punch and one V notch can work at the same time to produce transformer core pieces with 3, 5, 7 steps in vertical direction and 3, 5, 7 steps in horizontal direction.

As a professional electrical equipment manufacturer in China, Canwin specialized in dry type transformers, electrical equipment for over 20 years. Canwin electrical products manufacturer adopts large-scale, intelligent electrical machinery equipment manufacturing mode, and strive to achieve high quality, high efficiency, low cost operation.Our electrical machinery products including cut to length lines, china slitting lines and foil winding machines.

Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.

The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.

The transformer core provides a magnetic path to channel flux. The use of highly permeable material (which describes the material’s ability to carry flux), as well as better core construction techniques, helps provide a desirable, low reluctance flux path and confine lines of flux to the core. An electrical distribution cabinet is a part of an electrical system whose task is to distribute electrical energy. It includes distribution, protection, measurement, control and signaling instruments. The electrical distribution box also contains wires, various types of insulation, and support components. Read additional info on https://www.canwindg.com/

The metal laser cutting machine focuses the laser emitted from the laser into a laser beam with high power density through the optical path system. The laser beam irradiates the surface of the workpiece to make the workpiece reach the melting point or boiling point. At the same time, the high-pressure gas coaxial with the beam blows away the molten or gasified metal. With the movement of the relative position between the beam and the workpiece, the material will finally form a slit, so as to achieve the purpose of cutting. Laser cutting process uses invisible light beam to replace the traditional mechanical knife. It has the characteristics of high precision, fast cutting, not limited to the limitation of cutting pattern, automatic typesetting, material saving, smooth incision and low processing cost. It will gradually improve or replace the traditional metal cutting process equipment.Want to konw more about metal cutting machine, contact us, one of the most professional metal laser cutting machine manufacturers & suppliers in China.

As a professional energy storage system manufacturer, Canwin specialized in battery energy storage system and containerized energy storage system manufacturing. An energy storage system, often abbreviated as ESS, is a device or group of devices assembled together, capable of storing energy in order to supply electrical energy at a later time. In the energy storage systems, the lithium energy storage battery only interacts with the energy storage converter at high voltage, and the converter takes power from the AC grid to charge the battery pack. Or the battery pack supplies power to the converter, and the electric energy is converted into AC by the converter and sent to the AC power grid.

Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.